This document covers the molded and pultruded FRP grating we supply. Use it to select a mesh and a resin system, and to read the deflection at your support span.
- 1 . Molded grating - mesh and panel data
- 2 . Pultruded grating - series data
- 3 . Resin systems, flame class and oxygen index
- 4 . Load and deflection data
- 5 . How to use these tables
1 . Molded grating - mesh and panel data
Bar thickness is given as top / bottom. Open area affects drainage and ventilation; weight affects the support structure you need.
Molded grating meshes
| Mesh | Bar thickness top / bottom (mm) | Open area | Weight (kg/m²) | Panel sizes (mm) |
|---|---|---|---|---|
| 19*19H30 | 6.5 / 5.0 | 40% | 19.1 | 1220 x 4000, 1220 x 3660, 1220 x 2440, 915 x 3050 |
| 38*38H30 | 6.0 / 5.0 | 68% | 14.6 | 1524 x 4000, 1220 x 4000, 1220 x 3660, 1220 x 2440, 915 x 3050 |
| 50*50H50 | 8.0 / 6.0 | 78% | 23.7 | 1800 x 4000, 1524 x 4000, 1220 x 3660, 1220 x 2440, 915 x 3050 |
| 38*152H38 | 8.0 / 6.0 | 67% | 15.92 | 1220 x 3660, 1220 x 2440, 915 x 3050 |
| 38*38H50 | 11 / 9.0 | 56% | 42 | 1220 x 4000, 1220 x 3660, 1220 x 2440, 915 x 3050 |
| 25*152H38 | 7.0 / 5.0 | 62% | 23.1 | 565 x 3050 (stair tread panel) |
2 . Pultruded grating - series data
Pultruded grating carries load along one axis only. Plan the bearing bar direction before ordering.
Pultruded grating series
| Series | Load bar depth (mm) | Open area | Weight (kg/m²) | Panel sizes (mm) |
|---|---|---|---|---|
| I-4010 | 25 | 50% | 17.8 | 1220 or 915 wide x 3050 or 6100 long |
| HL-4020 | 50 | 40% | 70.37 | 1220 or 915 wide x 3050 or 6100 long |
| T-1210 | 25 | 12% | 14.5 | 1220 or 915 wide x 3050 or 6100 long |
| T-1215 | 38 | 12% | 19.6 | 1220 or 915 wide x 3050 or 6100 long |
| T-5020 | 50 | 50% | 15.66 | 1220 or 915 wide x 3050 or 6100 long |
3 . Resin systems, flame class and oxygen index
The number in a system code is the ASTM E84 flame spread index: a lower figure means the material spreads flame less, and 25 or less is the threshold normally specified as Class 1. Oxygen index is a separate measure of ignitability. Choose the resin by the chemical environment first; the chemical resistance document gives the data medium by medium.
Resin systems
| Our code | Base resin | ASTM E84 flame spread | Oxygen index | Specified for |
|---|---|---|---|---|
| VEFR-25 | Vinyl ester | 25 max | 28 min | Severe acids and alkalis; heavy-duty chemical service |
| VEFR-10 | Vinyl epoxy resin | 10 max | 35 min | As VEFR-25 where flame resistance also matters |
| IFR-25 | Isophthalic polyester | 25 max | 28 min | General industrial service, moderate chemical duty |
| IFGR-30 | Isophthalic polyester, food grade formulation | 30 max | 26 | Food processing areas |
| OFR-25 | Orthophthalic polyester | 25 max | 28 min | Water, sea water and neutral salts |
| OFR | Orthophthalic polyester | not rated | - | Non flame-retardant applications |
| MP-5 | Phenolic | 5 max | typically 80 | Maximum flame resistance and low smoke |
4 . Load and deflection data
Deflection is given in millimetres for the stated span and load. The limit load column is the failure threshold and must not be used as a working load.
19x19H30 - linear load, deflection (mm)
| Span (mm) | 75 kg/m | 150 kg/m | 300 kg/m | 450 kg/m | 750 kg/m | 1500 kg/m | Limit load (kg/m) |
|---|---|---|---|---|---|---|---|
| 300 | <0.25 | <0.25 | 0.25 | 0.51 | 0.76 | 1.52 | 9923 |
| 450 | 0.25 | 0.51 | 1.02 | 1.52 | 2.54 | 3.92 | 4827 |
| 600 | 0.51 | 1.27 | 2.29 | 3.56 | 5.84 | 7.38 | 4112 |
| 750 | 1.27 | 2.54 | 4.83 | 7.37 | 12.4 | 16.0 | 3174 |
| 900 | 2.27 | 4.54 | 9.08 | 13.6 | 18.7 | 22.1 | 2637 |
19x19H30 - uniform load, deflection (mm)
| Span (mm) | 350 kg/m² | 500 kg/m² | 750 kg/m² | 1000 kg/m² | 1500 kg/m² | 2500 kg/m² |
|---|---|---|---|---|---|---|
| 300 | 0.29 | 0.48 | 0.57 | 0.75 | 1.15 | 1.82 |
| 450 | 0.78 | 1.19 | 1.81 | 2.47 | 3.54 | 4.95 |
| 600 | 1.76 | 2.66 | 4.28 | 5.56 | 8.41 | 13.2 |
| 750 | 3.48 | 5.12 | 8.21 | 11.0 | 16.4 | — |
| 900 | 5.89 | 8.81 | 14.2 | 18.9 | — | — |
50x50H50 - limit load, linear (kg/m)
| 50*50H50 limit load | 300 mm | 600 mm | 900 mm | 1200 mm |
|---|---|---|---|---|
| Linear (kg/m) | 21727 | 11713 | 7780 | 5834 |
38x152H38 - limit load, linear and uniform
| 38*152H38 limit load | 300 mm | 450 mm | 600 mm | 750 mm | 900 mm | 1050 mm | 1200 mm |
|---|---|---|---|---|---|---|---|
| Linear (kg/m) | 12628 | 9946 | 8233 | 7040 | 6146 | 5439 | 5141 |
| Uniform (kg/m²) | 41358 | 26962 | 21716 | 18446 | 13420 | 10180 | 8418 |
5 . How to use these tables
- Choose the mesh by open area and weight: a larger mesh drains and ventilates better, a smaller mesh carries more load and stops small objects falling through.
- Choose the resin system by the chemical environment, not by price. See the oxygen index table above.
- Read the deflection table at your actual support span. A common working limit is L/100 for walkways and L/200 where a stiffer feel is required.
- Treat the limit load as a safety reference only. Design working loads well below it.
- Confirm the panel size against your opening before ordering; panels can be cut to size on request.